RESUMO

Our objective was to compare long-term outcomes in patients with non-ST-elevation myocardial infarction (NSTEMI) and ST-elevation myocardial infarction (STEMI) between two time periods in Southern Norway. There are limited contemporary data comparing long-term follow-up after revascularization in the last decades. This prospective follow-up study consecutively included both NSTEMI and STEMI patients during two time periods, 2014-2015 and 2004-2009. Patients were followed up for a period of 5 years. The primary outcome was all-cause mortality after 1 and 5 years. A total of 539 patients with acute myocardial infarction (AMI), 316 with NSTEMI (234 included in 2014 and 82 included in 2007) and 223 with STEMI (160 included in 2014 and 63 included in 2004). Mortality after NSTEMI was high and remained unchanged during the two time periods (mortality rate at 1 year: 3.5% versus 4.9%, p = 0.50; and 5 years: 11.4% versus 14.6%, p = 0.40). Among STEMI patients, all-cause mortality at 1 year was reduced in 2014 compared to 2004 (1.3% versus 11.1%, p < 0.001; and 5 years: 7.0% versus 22.2%, p = 0.004, respectively). Time to coronary angiography in NSTEMI patients remained unchanged between 2014 and 2007 (28.2 h [IQR 18.1-46.3] versus 30.3 h [IQR 18.0-48.3], p = 0.20), while time to coronary angiography in STEMI patients was improved in 2014 compared with 2004 (2.8 h [IQR 2.0-4.8] versus 21.7 h [IQR 5.4-27.1], p < 0.001), respectively. During one decade of AMI treatment, mortality in patients with NSTEMI remained unchanged while mortality in STEMI patients decreased, both at 1 and 5 years.

3.
J Am Soc Echocardiogr ; 36(7): 788-799, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36933849

RESUMO

AIMS: Assessment of left ventricular (LV) function by echocardiography is hampered by modest test-retest reproducibility. A novel artificial intelligence (AI) method based on deep learning provides fully automated measurements of LV global longitudinal strain (GLS) and may improve the clinical utility of echocardiography by reducing user-related variability. The aim of this study was to assess within-patient test-retest reproducibility of LV GLS measured by the novel AI method in repeated echocardiograms recorded by different echocardiographers and to compare the results to manual measurements. METHODS: Two test-retest data sets (n = 40 and n = 32) were obtained at separate centers. Repeated recordings were acquired in immediate succession by 2 different echocardiographers at each center. For each data set, 4 readers measured GLS in both recordings using a semiautomatic method to construct test-retest interreader and intrareader scenarios. Agreement, mean absolute difference, and minimal detectable change (MDC) were compared to analyses by AI. In a subset of 10 patients, beat-to-beat variability in 3 cardiac cycles was assessed by 2 readers and AI. RESULTS: Test-retest variability was lower with AI compared with interreader scenarios (data set I: MDC = 3.7 vs 5.5, mean absolute difference = 1.4 vs 2.1, respectively; data set II: MDC = 3.9 vs 5.2, mean absolute difference = 1.6 vs 1.9, respectively; all P < .05). There was bias in GLS measurements in 13 of 24 test-retest interreader scenarios (largest bias, 3.2 strain units). In contrast, there was no bias in measurements by AI. Beat-to-beat MDCs were 1,5, 2.1, and 2.3 for AI and the 2 readers, respectively. Processing time for analyses of GLS by the AI method was 7.9 ± 2.8 seconds. CONCLUSION: A fast AI method for automated measurements of LV GLS reduced test-retest variability and removed bias between readers in both test-retest data sets. By improving the precision and reproducibility, AI may increase the clinical utility of echocardiography.


Assuntos
Aprendizado Profundo , Disfunção Ventricular Esquerda , Humanos , Reprodutibilidade dos Testes , Inteligência Artificial , Função Ventricular Esquerda , Ecocardiografia/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Volume Sistólico
4.
Echocardiography ; 39(2): 233-239, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35043455

RESUMO

BACKGROUND: Noninvasive identification of significant coronary artery disease (CAD) in patients with unstable angina pectoris (UAP) is challenging. Exercise stress testing has been used for years in patients with suspected CAD but has low diagnostic accuracy. The use of Global longitudinal strain (GLS) by speckle tracking echocardiography is a highly sensitive and reproducible parameter for detection of myocardial ischemia. Our aim was to study if identification of normal or ischemic myocardium by measurement of GLS immediately after an ordinary bicycle exercise stress testing in patients with suspected UAP could identify or rule out significant CAD. METHODS: Seventy-eight patients referred for coronary angiography from outpatient clinics and the emergency department with chest pain, inconclusive ECG and normal values of Troponin-T was included. All patients underwent echocardiographic examination at rest and immediately after maximum stress by exercise on a stationary bicycle. Significant CAD was defined by diameter stenosis > 90% by coronary angiography. In patients with coronary stenosis between 50-90%, fractional flow reserve (FFR) was measured and defined abnormal < .80. Analysis of echocardiographic data were performed blinded for angiographic data. Patients were discharged diagnosed with CAD (n = 34) or non-coronary chest pain (NCCP, n = 44). RESULTS: In patients with NCCP, GLS at rest was -21.1 ± 1.7% and -25.5 ± 2.6% at maximum stress (P < .01). In patients with CAD, GLS at rest was -16.8 ± 4.0% and remained unchanged at maximum stress (-16.6 ± 4.6%, P = .69). In patients with NCCP, LVEF was 56.1% ± 6.0 and increased to 61.8% 5.2, P < .01. In CAD patients, LVEF at rest was 54.7% ± 8.6 and increased to 58.2% ± 9.5 during stress, P = .16. In NCCP patients, Wall Motion Score index decreased .02 ± .07, P = .03 during stress and was without significant changes in patients with CAD. Area under the curve (AUC) for distinguishing CAD for was .97 (.95-1.00), .63 (.49-.76), and .71 (.59-.83) for GLS, LVEF, and WMSi, respectively. CONCLUSION: In patients with suspected UAP, increased deformation of the left ventricle measured by GLS immediately after exercise stress testing identified normal myocardium without CAD. Reduced LV contractile function by GLS without increase after exercise identified significant CAD.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Angina Instável/complicações , Angina Instável/diagnóstico por imagem , Angiografia Coronária , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Teste de Esforço , Ventrículos do Coração/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
5.
Int J Cardiol ; 342: 56-62, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34324947

RESUMO

BACKGROUND: Recent evidence suggests that an implantable cardioverter defibrillator (ICD) in non-ischemic cardiomyopathy (NICM) may not offer mortality benefit. We aimed to investigate if etiology of heart failure and strain echocardiography can improve risk stratification of life threatening ventricular arrhythmia (VA) in heart failure patients. METHODS: This prospective multi-center follow-up study consecutively included NICM and ischemic cardiomyopathy (ICM) patients with left ventricular ejection fraction (LVEF) <40%. We assessed LVEF, global longitudinal strain (GLS) and mechanical dispersion (MD) by echocardiography. Ventricular arrhythmia was defined as sustained ventricular tachycardia, sudden cardiac death or appropriate shock from an ICD. RESULTS: We included 290 patients (67 ± 13 years old, 74% males, 207(71%) ICM). During 22 ± 12 months follow up, VA occurred in 32(11%) patients. MD and GLS were both markers of VA in patients with ICM and NICM, whereas LVEF was not (p = 0.14). MD independently predicted VA (HR: 1.19; 95% CI 1.08-1.32, p = 0.001), with excellent arrhythmia free survival in patients with MD <70 ms (Log rank p < 0.001). Patients with NICM and MD <70 ms had the lowest VA incidence with an event rate of 3%/year, while patients with ICM and MD >70 ms had highest VA incidence with an event rate of 16%/year. CONCLUSION: Patients with NICM and normal MD had low arrhythmic event rate, comparable to the general population. Patients with ICM and MD >70 ms had the highest risk of VA. Combining heart failure etiology and strain echocardiography may classify heart failure patients in low, intermediate and high risk of VA and thereby aid ICD decision strategies.


Assuntos
Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Idoso , Idoso de 80 Anos ou mais , Cardiomiopatia Dilatada/diagnóstico por imagem , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Volume Sistólico , Função Ventricular Esquerda
6.
JACC Cardiovasc Imaging ; 14(10): 1918-1928, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34147442

RESUMO

OBJECTIVES: This study sought to examine if fully automated measurements of global longitudinal strain (GLS) using a novel motion estimation technology based on deep learning and artificial intelligence (AI) are feasible and comparable with a conventional speckle-tracking application. BACKGROUND: GLS is an important parameter when evaluating left ventricular function. However, analyses of GLS are time consuming and demand expertise, and thus are underused in clinical practice. METHODS: In this study, 200 patients with a wide range of left ventricle (LV) function were included. Three standard apical cine-loops were analyzed using the AI pipeline. The AI method measured GLS and was compared with a commercially available semiautomatic speckle-tracking software (EchoPAC v202, GE Healthcare. RESULTS: The AI method succeeded to both correctly classify all 3 standard apical views and perform timing of cardiac events in 89% of patients. Furthermore, the method successfully performed automatic segmentation, motion estimates, and measurements of GLS in all examinations, across different cardiac pathologies and throughout the spectrum of LV function. GLS was -12.0 ± 4.1% for the AI method and -13.5 ± 5.3% for the reference method. Bias was -1.4 ± 0.3% (95% limits of agreement: 2.3 to -5.1), which is comparable with intervendor studies. The AI method eliminated measurement variability and a complete GLS analysis was processed within 15 s. CONCLUSIONS: Through the range of LV function this novel AI method succeeds, without any operator input, to automatically identify the 3 standard apical views, perform timing of cardiac events, trace the myocardium, perform motion estimation, and measure GLS. Fully automated measurements based on AI could facilitate the clinical implementation of GLS.


Assuntos
Inteligência Artificial , Ventrículos do Coração , Ecocardiografia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Função Ventricular Esquerda
7.
IEEE Trans Med Imaging ; 40(5): 1340-1351, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33493114

RESUMO

Deformation imaging in echocardiography has been shown to have better diagnostic and prognostic value than conventional anatomical measures such as ejection fraction. However, despite clinical availability and demonstrated efficacy, everyday clinical use remains limited at many hospitals. The reasons are complex, but practical robustness has been questioned, and a large inter-vendor variability has been demonstrated. In this work, we propose a novel deep learning based framework for motion estimation in echocardiography, and use this to fully automate myocardial function imaging. A motion estimator was developed based on a PWC-Net architecture, which achieved an average end point error of (0.06±0.04) mm per frame using simulated data from an open access database, on par or better compared to previously reported state of the art. We further demonstrate unique adaptability to image artifacts such as signal dropouts, made possible using trained models that incorporate relevant image augmentations. Further, a fully automatic pipeline consisting of cardiac view classification, event detection, myocardial segmentation and motion estimation was developed and used to estimate left ventricular longitudinal strain in vivo. The method showed promise by achieving a mean deviation of (-0.7±1.6)% compared to a semi-automatic commercial solution for N=30 patients with relevant disease, within the expected limits of agreement. We thus believe that learning-based motion estimation can facilitate extended use of strain imaging in clinical practice.


Assuntos
Aprendizado Profundo , Ecocardiografia , Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Humanos , Movimento (Física)
8.
Artigo em Inglês | MEDLINE | ID: mdl-32175861

RESUMO

Volume and ejection fraction (EF) measurements of the left ventricle (LV) in 2-D echocardiography are associated with a high uncertainty not only due to interobserver variability of the manual measurement, but also due to ultrasound acquisition errors such as apical foreshortening. In this work, a real-time and fully automated EF measurement and foreshortening detection method is proposed. The method uses several deep learning components, such as view classification, cardiac cycle timing, segmentation and landmark extraction, to measure the amount of foreshortening, LV volume, and EF. A data set of 500 patients from an outpatient clinic was used to train the deep neural networks, while a separate data set of 100 patients from another clinic was used for evaluation, where LV volume and EF were measured by an expert using clinical protocols and software. A quantitative analysis using 3-D ultrasound showed that EF is considerably affected by apical foreshortening, and that the proposed method can detect and quantify the amount of apical foreshortening. The bias and standard deviation of the automatic EF measurements were -3.6 ± 8.1%, while the mean absolute difference was measured at 7.2% which are all within the interobserver variability and comparable with related studies. The proposed real-time pipeline allows for a continuous acquisition and measurement workflow without user interaction, and has the potential to significantly reduce the time spent on the analysis and measurement error due to foreshortening, while providing quantitative volume measurements in the everyday echo lab.


Assuntos
Aprendizado Profundo , Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Volume Sistólico/fisiologia , Humanos , Processamento de Imagem Assistida por Computador , Função Ventricular Esquerda/fisiologia
9.
Cardiovasc Ultrasound ; 17(1): 18, 2019 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-31477137

RESUMO

BACKGROUND: Left ventricular ejection fraction (LVEF) is an established method for evaluation of left ventricular (LV) systolic function. Global longitudinal strain (GLS) by speckle tracking echocardiography seems to be an important additive method for evaluation of LV function with improved reproducibility compared with LVEF. Our aim was to compare reproducibility of GLS and LVEF between an expert and trainee both as echocardiographic examiner and analyst. METHODS: Forty-seven patients with recent Acute Coronary Syndrome (ACS) underwent echocardiographic examination by both an expert echocardiographer and a trainee. Both echocardiographers, blinded for clinical data and each other's findings, performed image analysis for evaluation of intra- and inter- observer variability. GLS was measured using speckle tracking echocardiography. LVEF was calculated by Simpson's biplane method. RESULTS: The trainee measured a GLS of - 19.4% (±3.5%) and expert - 18.7% (±3.2%) with an Intra class correlation coefficient (ICC) of 0.89 (0.74-0.95). LVEF by trainee was 50.3% (±8.2%) and by expert 53.6% (±8.6%), ICC coefficient was 0.63 (0.32-0.80). For GLS the systematic difference was 0.21% (- 4.58-2.64) vs. 4.08% (- 20.78-12.62) for LVEF. CONCLUSION: GLS is a more reproducible method for evaluation of LV function than LVEF regardless of echocardiographic training.


Assuntos
Síndrome Coronariana Aguda/diagnóstico , Cardiologia/educação , Competência Clínica , Ecocardiografia Tridimensional/métodos , Educação de Pós-Graduação em Medicina/métodos , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Síndrome Coronariana Aguda/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Sístole , Fatores de Tempo
11.
J Am Soc Echocardiogr ; 27(5): 512-9, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24612899

RESUMO

BACKGROUND: Many patients with suspected non-ST-segment elevation acute coronary syndrome (NSTE-ACS) do not have significant coronary artery disease. The current diagnostic approach of repeated electrocardiography and cardiac biomarker assessment requires observation for >6 to 12 hours. This strategy places a heavy burden on hospital facilities. The objective of this study was to investigate whether myocardial strain assessment by echocardiography could exclude significant coronary artery stenosis in patients presenting with suspected NSTE-ACS. METHODS: Sixty-four patients presenting to the emergency department with suspected NSTE-ACS without known coronary artery disease, inconclusive electrocardiographic findings, and normal cardiac biomarkers at arrival were enrolled. Twelve-lead electrocardiography, troponin T assay, and echocardiography were performed at arrival, and all patients underwent coronary angiography. Significant coronary stenosis was defined as >50% luminal narrowing. Global myocardial peak systolic longitudinal strain was measured using speckle-tracking echocardiography. Left ventricular ejection fraction and wall motion score index were calculated. RESULTS: No significant stenosis in any coronary artery was found in 35 patients (55%). Global peak systolic longitudinal strain was superior to conventional echocardiographic parameters in distinguishing patients with and without significant coronary artery stenosis (area under the curve, 0.87). Sensitivity and specificity were calculated as 0.93 and 0.78, respectively, and positive predictive value and negative predictive value as 0.74 and 0.92, respectively. Feasibility of the strain measurements was excellent, with 97% of segments analyzed. CONCLUSIONS: Myocardial strain by echocardiography may facilitate the exclusion of significant coronary artery stenosis among patients presenting with suspected NSTE-ACS with inconclusive electrocardiographic findings and normal cardiac biomarkers.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Ecocardiografia/métodos , Técnicas de Imagem por Elasticidade/métodos , Interpretação de Imagem Assistida por Computador/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Síndrome Coronariana Aguda/complicações , Estenose Coronária/complicações , Diagnóstico Diferencial , Diagnóstico Precoce , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/etiologia
12.
JACC Cardiovasc Imaging ; 6(8): 841-50, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23850251

RESUMO

OBJECTIVES: The aim of this study was to test the hypothesis that strain echocardiography might improve arrhythmic risk stratification in patients after myocardial infarction (MI). BACKGROUND: Prediction of ventricular arrhythmias after MI is challenging. Left ventricular ejection fraction (LVEF) <35% is the main parameter for selecting patients for implantable cardioverter-defibrillator therapy. METHODS: In this prospective, multicenter study, 569 patients >40 days after acute MI were included, 268 of whom had ST-segment elevation MIs and 301 non-ST-segment elevation MIs. By echocardiography, global strain was assessed as average peak longitudinal systolic strain from 16 left ventricular segments. Time from the electrocardiographic R-wave to peak negative strain was assessed in each segment. Mechanical dispersion was defined as the standard deviation from these 16 time intervals, reflecting contraction heterogeneity. RESULTS: Ventricular arrhythmias, defined as sustained ventricular tachycardia or sudden death during a median 30 months (interquartile range: 18 months) of follow-up, occurred in 15 patients (3%). LVEFs were reduced (48 ± 17% vs. 55 ± 11%, p < 0.01), global strain was markedly reduced (-14.8 ± 4.7% vs. -18.2 ± 3.7%, p = 0.001), and mechanical dispersion was increased (63 ± 25 ms vs. 42 ± 17 ms, p < 0.001) in patients with arrhythmias compared with those without. Mechanical dispersion was an independent predictor of arrhythmic events (per 10-ms increase, hazard ratio: 1.7; 95% confidence interval: 1.2 to 2.5; p < 0.01). Mechanical dispersion and global strain were markers of arrhythmias in patients with non-ST-segment elevation MIs (p < 0.05 for both) and in those with LVEFs >35% (p < 0.05 for both), whereas LVEF was not (p = 0.33). A combination of mechanical dispersion and global strain showed the best positive predictive value for arrhythmic events (21%; 95% confidence interval: 6% to 46%). CONCLUSIONS: Mechanical dispersion by strain echocardiography predicted arrhythmic events independently of LVEF in this prospective, multicenter study of patients after MI. A combination of mechanical dispersion and global strain may improve the selection of patients after MI for implantable cardioverter-defibrillator therapy, particularly in patients with LVEFs >35% who did not fulfill current implantable cardioverter-defibrillator indications.


Assuntos
Morte Súbita Cardíaca/etiologia , Ecocardiografia/métodos , Infarto do Miocárdio/diagnóstico por imagem , Taquicardia Ventricular/etiologia , Idoso , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Eletrocardiografia , Europa (Continente) , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Infarto do Miocárdio/complicações , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/terapia , Seleção de Pacientes , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Fatores de Risco , Volume Sistólico , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/prevenção & controle , Fatores de Tempo , Função Ventricular Esquerda
13.
J Am Soc Echocardiogr ; 24(10): 1118-25, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21764553

RESUMO

BACKGROUND: Early prediction of infarct size directs therapy in patients with acute myocardial infarction (AMI). Global strain by echocardiography describes myocardial deformation and correlates with infarct size. However, peak strain measures deformation at a single time point, whereas ischemia and necrosis influence deformation throughout the heart cycle. It was hypothesized that the measurement of myocardial deformation throughout the heart cycle by mean strain is a more comprehensive expression of myocardial deformation. The aim of this study was to assess the ability of mean strain to predict infarct size and to identify large infarctions at admission and after revascularization in patients with AMI. METHODS: Seventy-six patients with AMI were included. Echocardiographic measurements were performed at admission and after revascularization. Myocardial strain was calculated using speckle-tracking echocardiography. Infarct size was measured using contrast-enhanced magnetic resonance imaging ≥3 months after revascularization. RESULTS: There were significant correlations between infarct size and longitudinal global mean strain, longitudinal global strain, and left ventricular ejection fraction (P < .0001), both at admission and after revascularization. The correlations improved after revascularization. Longitudinal global mean strain had the best correlation with infarct size and the best ability to discriminate between different infarct size categories. At admission, a cutoff value of -7.6 had 89% sensitivity, 88% specificity, and an area under the receiver operating characteristic curve of 0.92 for the identification of large infarctions. Prediction of infarct size improved for all parameters after revascularization. CONCLUSIONS: Longitudinal global mean strain provides improved early prediction of infarct size in patients with AMI compared with longitudinal global strain and left ventricular ejection fraction.


Assuntos
Ecocardiografia/métodos , Frequência Cardíaca , Contração Miocárdica/fisiologia , Infarto do Miocárdio/diagnóstico por imagem , Volume Sistólico/fisiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/cirurgia , Revascularização Miocárdica , Valor Preditivo dos Testes , Prognóstico , Índice de Gravidade de Doença
14.
Eur J Echocardiogr ; 12(7): 483-9, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21609975

RESUMO

AIMS: Differentiation between necrotic and viable myocardium is difficult in the setting of acute myocardial infarction (MI). Post-systolic shortening (PSS) has been proposed as a marker of recovery after revascularization, but has not previously been assessed in patients with NSTEMI prior to revascularization. In this study, we aimed to examine the relation between PSS and improvement of contractile function after successful revascularization. METHODS AND RESULTS: Thirty-five patients with non-segment elevation MI and regional systolic dysfunction were examined immediately prior to revascularization, and at follow-up 9 ± 3 months after successful revascularization. Regional systolic function was assessed by speckle tracking echocardiography as regional strain, expressed as mean peak negative longitudinal strain in segments supplied by the culprit artery. Recovery of systolic function was assessed as the difference between regional strain at follow-up and baseline (ΔStrain). Post-systolic shortening was defined as shortening in diastole beyond minimum systolic length. By multivariate regression analysis, several other variables that may affect viability were also assessed. Post-systolic shortening was observed in 32 patients (91%), mean -1.9 ± 1.4%. Mean ΔStrain was -3.3 ± 2.9%. After adjustment for baseline systolic function, PSS (ß = 0.77, P= 0.022), and angiographic severity were independent predictors of viability by multiple regression analysis. Interestingly, troponin T was not a significant predictor. CONCLUSIONS: Post-systolic shortening is associated with improved myocardial function after revascularization in patients with acute MI. It predicts long-term systolic function, and provides information on the potential benefit of the procedure.


Assuntos
Infarto do Miocárdio/patologia , Miocárdio/patologia , Necrose/patologia , Sobrevivência de Tecidos , Angioplastia Coronária com Balão , Biomarcadores , Angiografia Coronária , Feminino , Hemodinâmica , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Prognóstico , Estudos Prospectivos , Índice de Gravidade de Doença , Estatística como Assunto , Volume Sistólico , Sístole , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
15.
Echocardiography ; 28(5): 556-63, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21535118

RESUMO

The aim of the study was to compare the ability of global strain and left ventricular ejection fraction (LVEF) to predict outcome after acute myocardial infarction (AMI). Left ventricular (LV) function was measured using strain by Doppler and LVEF in 77 patients. Measurements were performed at admission and after 10 ± 5 days. Outcome was measured as the combined end point of cardiac death, reinfarction and hospitalization for heart failure, unstable angina or life threatening arrhythmia. The patients were followed for 3.29 ± 1.59 years (range 0-5.22 years) and 17 cardiac events were registered. The cutoff value of LVEF was 44% for optimal prediction of outcome. We used LVEF ≤ 44% vs. > 44% and the corresponding global strain value ≥ -15.6% vs. < -15.6% to predict cumulative event-free survival. Both methods significantly predicted cardiac combined events at admittance and after 10 days with no difference. After 10 days, however, global strain remained the only significant predictor of outcome in a multivariate logistic regression model (P < 0.0001, odds ratio 1.79). Interobserver reproducibility measured as intraclass correlation was better for global strain than for LVEF (0.92 vs. 0.71). In conclusion, the measurement of global strain in patients with AMI may predict cardiac combined events to the same extent as LVEF in the acute phase and superior to LVEF after 10 days. In addition, global strain demonstrates better interobserver reproducibility and may become an improved bedside tool to evaluate LV function as a prognostic marker after AMI.


Assuntos
Ecocardiografia/métodos , Módulo de Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Avaliação de Resultados em Cuidados de Saúde , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Volume Sistólico , Disfunção Ventricular Esquerda/etiologia
16.
Heart ; 96(19): 1550-6, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20643662

RESUMO

OBJECTIVES: To compare infarct size and left ventricular ejection fraction in patients with non-ST-elevation myocardial infarction (NSTEMI) with and without acute coronary occlusions, and determine if myocardial strain by speckle-tracking echocardiography can identify acute occlusions in patients presenting with non-ST-elevation acute coronary syndrome (NSTE-ACS). METHODS: 111 patients with suspected NSTE-ACS were enrolled shortly after admittance. Echocardiographic measurements were performed a median of 1 h (interquartile range 0.5-4) after admittance, and coronary angiography 36 ± 21 h after onset of symptoms. Territorial longitudinal and circumferential strain was calculated based on the perfusion territories of the three major coronary arteries in a 16-segment model of the left ventricle, and compared with traditional echocardiographic parameters. Long-term follow-up was by echocardiography and contrast-enhanced magnetic resonance imaging (ceMRI). RESULTS: Patients with NSTEMI due to acute coronary occlusion had higher peak troponin T than patients with NSTEMI without acute occlusions (4.9 ± 4.7 vs 0.9 ± 1.1 µg/l, p<0.001), larger infarct size by ceMRI (13 ± 8% vs 3 ± 3%, p<0.001) and poorer left ventricular ejection fraction (48 ± 6% vs 57 ± 6%, p<0.001) at follow-up. Territorial circumferential strain was the best parameter for predicting acute coronary occlusion. A territorial circumferential strain value >-10.0% had 90% sensitivity, 88% specificity and area under the curve=0.93 for identification of acute occlusions. CONCLUSIONS: Patients with NSTEMI due to acute coronary occlusions develop larger infarcts and more impaired left ventricular function than patients with NSTEMI without occlusions, regardless of infarct-related territory. Territorial circumferential strain by echocardiography enables very early identification of acute coronary occlusions in patients with NSTE-ACS and may be used for detection of patients requiring urgent revascularisation.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Oclusão Coronária/diagnóstico por imagem , Ecocardiografia/métodos , Síndrome Coronariana Aguda/patologia , Síndrome Coronariana Aguda/fisiopatologia , Idoso , Biomarcadores/sangue , Angiografia Coronária , Oclusão Coronária/patologia , Oclusão Coronária/fisiopatologia , Diagnóstico Precoce , Feminino , Humanos , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/fisiopatologia , Volume Sistólico/fisiologia , Troponina T/sangue
17.
Am J Cardiol ; 105(9): 1212-8, 2010 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-20403468

RESUMO

The optimal timing of coronary angiography in patients with non-ST elevation (NSTE) acute coronary syndromes (ACS) is debated. American Heart Association and American College of Cardiology guidelines recommend an early invasive strategy <12 to 48 hours after the onset of symptoms. The objective of the present study was to determine possible changes in myocardial function in patients with NSTE ACS awaiting coronary angiography. One hundred two patients with suspected NSTE ACS were enrolled, including 56 with NSTE myocardial infarctions (NSTEMIs), 23 with unstable angina pectoris, and 23 with noncoronary chest pain. Global and regional myocardial function was measured as longitudinal and circumferential strain using speckle-tracking echocardiography. Measurements were performed at admission and immediately before coronary angiography (30 + or - 16 hours after admission). In patients with NSTEMIs, there was deterioration in longitudinal global strain from -16.1 + or - 2.6% at admission to -15.0 + or - 2.6% before coronary angiography (p <0.001). This was due to deterioration in longitudinal strain in the territory supplied by the infarct-related artery from -14.2 + or - 4.2% to -12.0 + or - 4.1% (p <0.001). Patients with NSTEMIs due to acute coronary occlusion underwent prominent worsening in longitudinal and circumferential strains (-15.7 + or - 2.9% to -13.9 + or - 3.0%, p = 0.001, and -16.7 + or - 4.0% to -15.0 + or - 3.9%, p = 0.01, respectively) compared to patients with NSTEMIs without occlusions. There were no changes in strain in patients with unstable angina pectoris or noncoronary chest pain. In patients with NSTEMIs without acute coronary occlusions, myocardial function improved after revascularization, whereas patients with acute occlusions demonstrated no improvement. In conclusion, myocardial function deteriorates in patients with NSTEMIs awaiting coronary angiography. Patients with acute coronary occlusions have the most prominent deterioration, and this subgroup shows no recovery of function after revascularization.


Assuntos
Síndrome Coronariana Aguda/fisiopatologia , Angiografia Coronária , Eletrocardiografia , Contração Miocárdica/fisiologia , Síndrome Coronariana Aguda/diagnóstico , Idoso , Diagnóstico Diferencial , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Fatores de Tempo
18.
Eur J Echocardiogr ; 11(6): 501-8, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20185525

RESUMO

AIMS: Patients with acute coronary occlusion may lack typical signs of myocardial infarction in the electrocardiogram. We tested the ability of different echocardiographic modalities to identify coronary occlusion by quantifying myocardial dysfunction in patients with non-ST-elevation acute coronary syndrome (NSTE-ACS). METHODS AND RESULTS: One hundred and fifty patients were examined by echocardiography immediately prior to coronary angiography, 2.2 +/- 0.7 days (mean +/- SD) after hospitalization for a first NSTE-ACS. Thirty-three patients (22%) had acute coronary occlusion. These patients had impaired left ventricular function as ejection fraction was reduced (54.9 +/- 9.6 vs. 59.1 +/- 7.6%, P = 0.02). Regional myocardial function was assessed in a 16-segment model by two methods: longitudinal strain by speckle tracking echocardiography and wall motion score (WMS) by visual assessment. Patients with acute coronary occlusion had an increased number of adjacent dysfunctional segments. The median size of the dysfunctional area by strain was 7 [inter-quartile range (IQR) 4.5-9] vs. 2 (IQR 0-5) segments (P < 0.001). An area of >or=4 adjacent dysfunctional segments (strain greater than or equal to -14%) had the best ability to identify patients with acute coronary occlusion, with sensitivity 85% and specificity 70%. WMS demonstrated slightly less accuracy than strain. CONCLUSION: Strain echocardiography identifies NSTE-ACS patients with acute coronary occlusion, who may benefit from urgent reperfusion therapy.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Ecocardiografia/instrumentação , Infarto do Miocárdio/diagnóstico por imagem , Síndrome Coronariana Aguda/patologia , Biomarcadores , Estenose Coronária/patologia , Ecocardiografia/métodos , Feminino , Indicadores Básicos de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Curva ROC , Medição de Risco , Estatística como Assunto , Volume Sistólico , Sístole , Troponina T , Função Ventricular Esquerda
19.
Circ Cardiovasc Imaging ; 3(2): 187-94, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20075142

RESUMO

BACKGROUND: Infarct size is a strong predictor of mortality and major adverse cardiovascular events after myocardial infarction. Acute reperfusion therapy limits infarct size and improves survival, but its use has been confined to patients with ST-segment-elevation myocardial infarction. The purpose of this study was to assess the relationship between echocardiographic parameters of left ventricular (LV) systolic function obtained before revascularization and final infarct size in patients with non-ST-segment-elevation myocardial infarction, as well as the ability of these parameters to identify patients with substantial infarction. METHODS AND RESULTS: Sixty-one patients with non-ST-segment-elevation myocardial infarction were examined by echocardiography immediately before revascularization, 2.1+/-0.6 days after hospitalization. LV systolic function was assessed by ejection fraction, wall motion score index, and circumferential, longitudinal, and radial strain in a 16-segment LV model. Global strain represents average segmental strain values. Infarct size was assessed after 9+/-3 months by late-enhancement MRI, as a percentage of total LV myocardial volume. A good correlation was found between infarct size and wall motion score index (r=0.74, P<0.001) and global longitudinal strain (r=0.68, P<0.001). Global longitudinal strain >-13.8% and wall motion score index >1.30 accurately identified patients with substantial infarction (> or =12% of myocardium, n=13; area under the receiver operator curve, 0.95 and 0.92, respectively). CONCLUSIONS: Echocardiographic parameters of LV systolic function correlate to infarct size in patients with non-ST-segment-elevation myocardial infarction. Global longitudinal strain and wall motion score index are both excellent parameters to identify patients with substantial myocardial infarction, who may benefit from urgent reperfusion therapy.


Assuntos
Ecocardiografia sob Estresse/métodos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Distribuição de Qui-Quadrado , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/tratamento farmacológico , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Análise de Regressão , Reprodutibilidade dos Testes , Fatores de Risco , Sístole
20.
Tidsskr Nor Laegeforen ; 129(23): 2479-82, 2009 Dec 03.
Artigo em Norueguês | MEDLINE | ID: mdl-19997136

RESUMO

BACKGROUND: Discomfort because of palpitation and tachycardia is a frequent phenomenon. Clinical practice for diagnosing tachycardia has a low sensitivity, and patients without a correct diagnosis are often not treated optimally. MATERIAL AND METHODS: Results from all 24-hour-ECGs taken at Telemark Hospital in the period 1.8.04-31.7.05 were reviewed. Indications and findings were retrieved from the hospital database. 252 of totally 614 ECGs were performed for the indications palpitation and tachycardia. 137 patients with an unclear diagnosis were offered a simple electrophysiologic examination with stimulation of the right atrium by a pacemaker electrode. 38 of these patients were included and underwent the examination. An additional 18 patients were referred to a simple electrophysiologic examination based on the same criteria. RESULTS: 24-hour-ECG provided a diagnosis for 29 patients with palpitation and tachycardia. A simple electrophysiologic examination uncovered reentry tachycardia in nine patients and paroxystic atrial flutter in three patients. A total of 56 electrophysiologic examinations were performed, uncovering 12 cases of tachycardia suitable for ablation. Two patients had to undergo DC-conversion, no other complication was observed. INTERPRETATION: A simplified electrophysiologic examination of this group of patients will uncover tachycardia suitable for ablation in approximately 20 % of the patients, and increase diagnostic yield of supraventricular tachycardia by 64 %.


Assuntos
Arritmias Cardíacas/diagnóstico , Técnicas Eletrofisiológicas Cardíacas/métodos , Taquicardia/diagnóstico , Adolescente , Adulto , Arritmias Cardíacas/fisiopatologia , Diagnóstico Diferencial , Eletrocardiografia , Feminino , Humanos , Masculino , Sensibilidade e Especificidade , Inquéritos e Questionários , Taquicardia/fisiopatologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...